Abstract
AbstractUp to now, tremendous efforts have been devoted to modelling the oxygen transfer coefficient (kLa) for diffused aeration systems, while not considering the corresponding energy consumption. Enhancing kLa is favorable for an exemplary oxygenation process, but may come at the cost of greater energy withdrawal, an unwelcome tradeoff. Assessing the aeration efficiency (the rate of oxygen delivered per unit energy) reflects the overall effectiveness of an aeration process and guarantees a superior system performance. Presented here is a lab‐scale study that investigates the effect of the orifice diameter, the airflow rate and the water column on the aeration efficiency. Various combinations of the studied parameters were tested using a cylindrical tank with a single orifice for air injection. An optimal performance of the aeration efficiency was observed at an orifice diameter of 0.3 mm when tested under 0.91 m water column and an airflow rate of 0.05 SLPM. Furthermore, a new empirical formula of aeration efficiency was established with a high correlation index (R2 = 0.97) to allow preliminary prediction of aeration efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.