Abstract

Correlated double sampling (CDS) circuits are essential to processing the X-ray charge-coupled devices (CCDs) that have been used in the modern X-ray astronomical field. For spectroscopy observations, the energy resolution is of decisive importance. In this paper, a comprehensive study of the CDS algorithm based on the incremental $\Delta \Sigma $ technique, named $\Delta \Sigma $ -CDS algorithm hereafter, is studied. Theoretical and practical aspects for modulations and demodulations for applications with different pixel rates (PRs) are discussed. The concepts of differential cascade-of-integrator filter and truncated cascaded-integrator-comb filter are extensively investigated from both the time-domain and frequency-domain analyses. The operating principles, prototype design, and experimental results are addressed. As a prototype for 100-kHz PR, a readout integrated circuit (ROIC) is designed. When tested with the target X-ray CCD–CCD236 using a $1~\mu $ Ci 55Fe radioisotope, the ROIC achieves an energy resolution characterized by the full-width-at-half-maximum as 132.4 ± 2.4 eV at 5.9 keV, which is very close to the 121-eV limit of CCD236.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.