Abstract

We carried out a vibration study experiment on a masonry building in the town of Ariano Irpino, southern Italy, using six-channel stations equipped with three-component velocity-transducers and accelerometers and running in continuous modality from January 2006 to December 2007. The analysis of weak motions from several local earthquakes, together with the 3D numerical modelling of the structure, allowed us to identify the first three vibration modes of the target building. Therefore, we checked the validity of ambient noise data to determine the vibration frequencies of buildings. The analysis tools based on earthquake and ambient noise data were conventional, i.e. spectral ratios between homologous components of stations at high floors in the building with respect to a station installed at the basement, and single-station spectral ratios between horizontal and vertical components. The indications derived from earthquakes and ambient noise result in a satisfactory agreement for frequencies between 1 and 20 Hz when using recordings characterized by low levels of amplitude, both for cultural and meteorological noise. In contrast, when the wind speed increases (above 20 km/h, approximately) seismic noise shows an excess of horizontal vibrations at low frequencies (below 2 Hz). These extra-amplitudes are not related to the seismic input vertically incident to the basement, but are probably due to the lateral action of the wind on the building. In contrast anthropic activities do not affect considerably the trend of spectral ratios in the range of frequencies that include the first modes of vibration of the building, even at high noise level.

Highlights

  • Ambient vibrations are largely used in seismology and earthquake engineering to investigate the seismic response of sites

  • Remarks The combined use of earthquakes recordings and numerical modelling allowed us to interpret the seismic response of the study building in the linear domain

  • Numerical modelling are not able to reproduce all the resonant frequencies obtained from experimental data with high accuracy [Lin et al

Read more

Summary

Introduction

Ambient vibrations are largely used in seismology and earthquake engineering to investigate the seismic response of sites. SSRs, between receivers at different floors and a reference station installed below the ground level are used to compute transfer functions along vertical profiles in the building. We assume that the recorded signal at the basement (A0) of the building is the reference input representative of the incident seismic radiation. This approximation is acceptable under the assumption that soil-structure interaction is negligible [Trifunac et al 2001, Kotronis et al 2013]. Transfer functions based on ratios of Fourier Spectral Amplitudes are calculated separately at the different stations for each of the selected events and for each component of motion.

D1 10 A2 B2 C2 D2
7.80 Hz f obs 3
Findings
Discussion and Concluding
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.