Abstract

A power source is presented capable of providing ac currents with amplitudes of up to 50 A and frequencies near 10 kHz. The current amplification is actively stabilized and exhibits fractional current noise better than one part in 105. The source was developed for use with an atom interferometer based on magnetically trapped condensate atoms. The relationship between current noise and interferometer noise is developed, and it is shown that the demonstrated precision should permit interferometry with coherence times of 1 s or more.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.