Abstract

The Radium burden of living mammals is usually obtained by measuring both the gamma-ray activity of the Ra(B + C) retained in the body and the time rate at which radon is lost in the breath. Whereas the first can be done consistently with satisfactory accuracy (1), relevance of the latter measurement is predicted on the assumption that, at the time of sampling, the rate of radon exhalation equals the rate of radon release from the radium deposits in the body. Since the radon exhalation rate of a single subject may vary over short periods of time (2), experimental results are beset by annoying uncertainties, which can be minimized at best by repeated sampling in the case of man and can be effectively eliminated only by periodic sacrifice and Ra assay when dealing with laboratory animals. The method to be discussed here consists in comparing with a scintillation spectrometer the relative intensities of the Ra226 and RaB gamma rays emitted by an animal to those of suitably prepared standards, and in evaluating by these means the fraction of radon retained. It should be realized at the outset that whereas RaB emits gamma rays of 240, 295 and 350 kev in numbers comparable to its rate of disintegration, Ra226 emits instead a 50 per cent internally converted gamma ray of 186 kev in only approximately 6 per cent of its disintegrations. Despite this small probability of emission, the gamma ray in question is easily detected by scintillation spectrometers in Ra sources where radon is present in amounts lower than 50 per cent equilibrium, as is true of radium-burdened mammals. Some idea of the possibilities involved can be gathered by inspection of Figures 1 and 2, which show some preliminary results obtained under conditions described in the legends. Apparatus Either NaI(T1) or CsI(T1) cylindrical crystals, 1.5 inches in diameter, sealed in aluminum containers (3), were used as scintillators. They were coupled optically to a 6292 Dumont photomultiplier tube connected in turn to the inputs of two single-channel analyzers. One of these was adjusted to cover a 35-kev-wide band of the spectrum centered over the 186-kev photopeak of Ra26, and the other to record pulses over a 200-kev band astride those emitted by RaB. Correct adjustment of the channels was effected by motorized scanning of the spectrum of a Ra source in air with the instruments feeding a count rate meter and strip chart recorder. The simultaneous reading of the two bands curtailed the necessary recording time and eliminated errors arising from uncontrollable motions of the animal. Before proceeding further, it is well to recall that the interaction of monoergic photons with a scintillator leads to the production of light pulses by photoelectrons and Compton-recoil electrons released in the crystal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.