Abstract

Monitoring mechanical stresses in microchannels is challenging. Herein, we report the development of a mechanofluorescence sensor system featuring a fluorogenic single polydiacetylene (PDA) particle, fabricated using a co-flow microfluidic method. We construct a stenotic vessel-mimicking capillary channel, in which the hydrodynamically captured PDA particle is subjected to controlled fluid flows. Fluorescence responses of the PDA particle are directly monitored in real time using fluorescent microscopy. The PDA particle displays significant nonlinear fluorescence emissions influenced by fluid viscosity and the presence of nanoparticles and biomolecules in the fluid. This nonlinear response is likely attributed to the torsion energy along the PDA’s main chain backbone. Computational fluid dynamic simulations indicate that the complete blue-to-red transition necessitates ~307 μJ, aligning with prior research. We believe this study offers a unique advantage for simulating specific problematic regions of the human body in an in vitro environment, potentially paving the way for future exploration of difficult-to-access areas within the body.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.