Abstract
The performances of hyaluronic acid (HA) purification (yield, purity, permeate flow rate and productivity) in a semi-synthetic medium composed of salts, proteins/peptides by diafiltration through a 100kDa PES membrane were studied over 10 diavolumes (DV). The HA purity went from 3% to almost 100% with a yield in the retentate close to 100% at the end of the process. The permeate flow rate showed a peculiar trend due to the influence of charged microsolutes. DF mass balance applied to three groups of solutes (HA, peptides/proteins and charged microsolutes) allowed a good prediction of HA yield and purity in the course of DF. An equation of the permeate flux based on limit flux equation, correlations between mass transfer coefficient mineral concentration and mineral mass balance was proposed to predict the process productivity. Eventually, a methodology based on these equations was proposed to predict HA yield, purity and productivity. The methodology was validated with an actual Streptococcus zooepidemicus broth. Differences between calculations and experimental performances in term of yield, purity and productivity never exceeded 10%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.