Abstract

An effective and fast method for determination of deoxynivalenol (DON) in cereals and flours has been developed. The immunoaffinity column was used for the isolation of DON from wheat, corn, rice and flour extract. The determination was carried out by using the HPLC/UV method. The limit of detection was 0.02 mg/kg. The recoveries for the assay range 0.1 to 2 mg/kg were generally higher than 80%, ranging from 83 to 96% with an average relative standard deviation of 3.8%. The trueness of the method using the DON test – HPLC column was established by use of certified reference material CRM 379. The certified value was 0.67 mg/kg. The result obtained from three replicates was 0.68 ± 0.05 mg/kg. The corresponding confidence interval at 95% probability ranged from 0.63 to 0.73 mg/kg. A comparative study of the DON testTM – HPLC/UV and the Mycosep 225 – GC/ECD methods was carried out. Six naturally contaminated wheat samples were analysed by both methods. Linear regression analysis demonstrates that DON testTM – HPLC is a statistically significant predictor of the GC/ECD method using the Romer Mycosep 225 column.  

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.