Abstract

Boron and phosphorus contaminants are difficult to detect in cleanrooms for semiconductor manufacturing due to their typically low concentration levels. In this paper, a new technique for detecting such contaminants that significantly reduces sampling time, from 24 h to less than 2 h, and avoids wafer congenital contamination interference, is proposed. An oversaturated nucleation approach extracts boron and phosphorus contaminants to show regional contaminant concentration differences rapidly. This method is simple, express, robust, and reliable. Moreover, it has been tested on site in wafer fabrication plants. The generic sampling framework can be refined and applied to metallic, dopant and other low-concentration contaminants in cleanrooms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.