Abstract

A sequential algorithm is developed for the non-linear dual-sorption model developed by Chandrasekaran et al. [1,2] which monitors pharmacokinetic profiles in percutaneous drug absorption. In the experimental study of percutaneous absorption, it is often observed that the lag-time decreases with the increase in the donor concentration when two or more donor concentrations of the same compound are used. The dual-sorption model has sometimes been employed to explain such experimental results. In this paper, it is shown that another feature observed after vehicle removal may also characterize the dual-sorption model. Soon after vehicle removal, the plots of the drug flux versus time become straight lines on a semilogarithmic scale as in the linear model, but the half-life is prolonged thereafter when the dual-sorption model prevails. The initial half-life after vehicle removal with a low donor concentration is longer than that with a higher donor concentration. These features, if observed in experiments, may be used as evidence to confirm that the dual-sorption model gives an explanation to the non-linear kinetic behaviour of a permeant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.