Abstract
A simple and robust sensorless technique for online stator winding turn fault detection based on monitoring an off-diagonal term of the sequence component impedance matrix is proposed in this paper. Due to the destructive and rapidly propagating nature of insulation failure, it is critical to detect turn faults in an early stage to minimize the financial loss. The motor nonidealities such as the variation in the supply voltage unbalance, slip-dependent influence of inherent motor asymmetry, and measurement errors must be taken into account in order to reliably detect a turn fault in its incipient stage. Simulation and experimental results on a 5 hp induction machine are given to confirm the validity of the proposed method. It is shown that the proposed turn fault detection scheme is simple and is capable of providing reliable fault detection that is immune to the motor nonidealities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.