Abstract

Patients on standard intermittent haemodialysis suffer from strong fluctuations in plasma potassium and phosphate. Prolonged dialysis with a wearable device, based on continuous regeneration of a small volume of dialysate using ion exchangers, could moderate these fluctuations and offer increased clearance of these electrolytes. We report in vivo results on the efficacy of potassium and phosphate adsorption from a wearable dialysis device. We explore whether equilibration of ion exchangers at physiological Ca 2+ , Mg 2+ and hypotonic NaCl can prevent calcium/magnesium adsorption and net sodium release, respectively. Effects on pH and HCO3- were studied. Healthy goats were instrumented with a central venous catheter and dialysed. Potassium and phosphate were infused to achieve plasma concentrations commonly observed in dialysis patients. An adsorption cartridge containing 80 g sodium poly(styrene-divinylbenzene) sulphonate and 40 g iron oxide hydroxide beads for potassium and phosphate removal, respectively, was incorporated in a dialysate circuit. Sorbents were equilibrated and regenerated with a solution containing NaCl, CaCl 2 and MgCl 2 . Blood was pumped over a dialyser and dialysate was recirculated over the adsorption cartridge in a countercurrent direction. Potassium and phosphate adsorption was 7.7 ± 2.7 and 4.9 ± 1.3 mmol in 3 h, respectively. Adsorption capacity remained constant during consecutive dialysis sessions and increased with increasing K + and PO43-. Equilibration at physiological Ca 2+ and Mg 2+ prevented net adsorption, eliminating the need for post-cartridge calcium and magnesium infusion. Equilibration at hypotonic NaCl prevented net sodium release Fe 2+ and arterial pH did not change. Bicarbonate was adsorbed, which could be prevented by equilibrating at HCO3- 15 mM. We demonstrate clinically relevant, concentration-dependent, pH-neutral potassium and phosphate removal in vivo with small volumes of regenerable ion exchangers in our prototype wearable dialysis device. Application of the selected ion exchangers for potassium and phosphate removal in a wearable dialysis device appears to be effective with a low-risk profile.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.