Abstract

This paper deals with power quality improvement using a three-phase active power filter (APF) connected to a PV power system. A direct power control (DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point (MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.