Abstract
A beam line U2A for microscopy, SEXAFS, and soft X-ray holography is being designed at NSRL, USTC, China. A preliminary design for U2A is presented, utilizing a linear monochromator consisting of a zone plate and a diaphragm. The parameters for these elements are as follows: the condenser zone plate has D = 6.0m,N = 10000, δRn = 0.15 μm, and F = 204.5 mm. The diaphragm has d = 24 μm. A spectral resolution λ/ Δλ = 125 would be achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods In Physics Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.