Abstract

BackgroundIn respiratory distress syndrome, many neonatology centers worldwide perform minimal invasive surfactant application in premature infants, using small-diameter catheters for endotracheal intubation and surfactant administration.MethodsIn this single-center, open-label, randomized-controlled trial, preterm infants requiring surfactant administration after birth, using a standardized minimal invasive protocol, were randomized to two different modes of endotracheal catheterization: Flexible charrière-4 feeding tube inserted using Magill forceps (group 1) and semi-rigid catheter (group 2). Primary outcome was duration of laryngoscopy. Secondary outcomes were complication rate (intraventricular hemorrhage, soft-tissue damage in first week of life) and vital parameters during laryngoscopy. Between 2019 and 2020, 31 infants were included in the study. Prior to in-vivo testing, laryngoscopy durations were studied on a neonatal airway mannequin in students, nurses and doctors.ResultsMean gestational age and birth weight were 27 + 6/7 weeks and 1009 g; and 28 + 0/7 weeks and 1127 g for group 1 and 2, respectively. Length of laryngoscopy was similar in both groups (61.1 s and 64.9 s) overall (p.77) and adjusted for weight (p.70) or gestational age (p.95). Laryngoscopy failed seven times in group 1 (43.8%) and four times (26.7%) in group 2 (p.46). Longer laryngoscopy was associated with lower oxygen saturation with lowest levels occurring after failed laryngoscopy attempts. Secondary outcomes were similar in both groups. In vitro data on 40 students, 40 nurses and 12 neonatologists showed significant faster laryngoscopy in students and nurses group 2 (p < .0001) unlike in neonatologists (p.13).ConclusionThis study showed no difference in laryngoscopy duration in endotracheal catheterization when comparing semi-rigid and flexible catheters for minimal invasive surfactant application in preterm infants. In accordance with preliminary data and in contrast to published in-vitro trials, experienced neonatologists were able to perform endotracheal catheterization using both semi-rigid and flexible catheters at similar rates and ease, in vitro and in vivo.Trial registrationClinicalTrials.gov. NCT05024435 Registered 27 August 2021—Retrospectively registered.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.