Abstract

Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (lamda) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant (PST lamda) was then compared to those determined by TLD (TLD lamda) and Monte Carlo (MC lamda) techniques. A likely consensus lamda value was estimated as the arithmetic mean of the average lamda values determined by each of three different techniques. The average PST lamda value for the three Advantage sources was found to be (0.676 +.- 0.026) cGyh(-1) U(-1). Intersource variation in PST lamda was less than 0.01%. The PST lamda was within 2% of the reported MC lamda values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported TLD lamda. A likely consensus lamda value was estimated to be (0.688 +/- 0.026) cGyh(-1) U(-1), similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686 +/- 0.033) cGyh(-1) U(-1), the NASI (Chatsworth, CA) Model MED3633 (0.688 +/- 0.033) cGyh(-1) U(-1), and the Best Medical (Springfield, VA) Model 2335 (0.685 +/- 0.033) cGyh(-1) U(-1) 103Pd sources. An independent lamda determination has been performed for the Advantage Pd-103 source. The PST lamda obtained in this work provides additional information needed for establishing a more accurate consensus lamda value for the Advantage Pd-103 source.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.