Abstract
The paper presents the results of a parametric study, using finite element analysis, of the behaviour of full face metal-to-metal taper-hub flanges. The important stress values in the flange have been obtained for a range of flange thickness, taper-hub thickness and length, when the shell/flange component is subject to internal pressure. The influence of the pre-stress in the bolts is examined. The results obtained have been compared with the predictions from the appropriate sections of the ASME, BS and the new European Unfired Pressure Vessel Standard (Draft BS: prEN 13445).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Pressure Vessels and Piping
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.