Abstract

A honeycomb girder (HCG) is defined by a mirror symmetric arrangement of two trapezoidal corrugated steel sheets (TCSS). Mechanical fasteners such as screws or rivets connect them. The high bending stiffness of HCGs provides the opportunity to span distances up to 14.0 m. Especially in the application as a cladding of roofs and facades of industrial steel-framed buildings this new construction type promises the potential to improve the resource and economic efficiency of these buildings. Former experimental investigations verified a numerical model. Based on this finite element method (FEM) model a parametric study on HCGs with an equidistant fastener arrangement has been carried out. By applying three design criteria on the numerical results the maximum characteristic surface loads for 360 HCG constellations have been determined. This paper investigates the influence of a graduated arrangement of mechanical fasteners in HCG systems on their maximum characteristic surface load.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.