Abstract
This research presents a numerical investigation on the behaviour of through rib stiffener steel beam connected to circular concrete-filled steel tube (CFT) column subjected to the cyclic loading. A nonlinear Finite Element (FE) model was established using ABAQUS/Standard program. The accuracy of the FE result was examined through comparing it with the previous experimental test results. The effects of various parameters on the failure mode and ultimate moment capacity of the connections were investigated on twenty-four FE models. The parameters were stiffener’ height, length, and thickness including varied thicknesses and diameters of the hollow circular steel tube. The FE results indicated that the larger height of the through rib stiffener improved buckling behaviour of the steel tube column and the moment capacity by 8%. Meanwhile, the longer and thicker through rib stiffener effectively shifted the beam plastic hinge’s location away from the column, which resulted in 4% improvement in ultimate moment capacity of the connection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Engineering Science and Technology, an International Journal
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.