Abstract

A novel method is presented to estimate exfiltration from sewer systems using artificial tracers. The method relies upon use of an upstream indicator signal and a downstream reference signal to eliminate the dependence of exfiltration estimates on the accuracy of discharge measurement. An experimental design, a data analysis procedure, and an uncertainty assessment process are described and illustrated by a case study. In a 2‐km reach of unknown condition, exfiltration was estimated at 9.9 ± 2.7%. Uncertainty in this estimate was primarily due to the use of sodium chloride (NaCl) as the tracer substance. NaCl is measured using conductivity, which is present at nonnegligible levels in wastewater, thus confounding accurate identification of tracer peaks. As estimates of exfiltration should have as low a measurement error as possible, future development of the method will concentrate on improved experimental design and tracer selection. Although the method is not intended to replace traditional CCTV inspections, it can provide additional information to urban water managers for rational rehabilitation planning.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.