Abstract

To the Editor: A number of ventilation strategies exist for patients with Montgomery T-tubes during tracheal resection. We describe a novel technique with antegrade passage of a Fogarty catheter through the mouth, guided by a suture to the upper limb of the T-tube. Written consent for publication of this article was obtained from the patient. A 59-yr-old female patient (weight 89 kg, height 173 cm) diagnosed with idiopathic tracheal stenosis was scheduled to undergo tracheal resection. A computed tomography scan of her neck showed tracheal stenosis 1.3 cm in length located 1.5 cm below the glottis. In the operating room, standard monitoring was applied and the patient was anesthetized with remifentanil, propofol bolus and infusion, and rocuronium. The patient’s lungs were ventilated with 100% oxygen with bag and mask for two minutes. Serial rigid bronchoscopies were performed up to 8.0 mm, and a size 6.5 mm (internal diameter) armoured tracheal tube was inserted into the trachea under direct laryngoscopy. The surgeons proceeded with a 3-cm cricotracheal resection with thyrotracheal anastomosis. During the resection, the patient’s lungs were ventilated with an armoured tracheal tube attached to the distal trachea just below the second ring. Later, during the anastomosis, the armoured tracheal tube was removed from the distal trachea. A size 11 mm (outer diameter) Montgomery T-tube (LT-511) (E. Benson Hood Laboratories, Inc, Pembroke, MA, USA) was inserted into the trachea to serve as a stent, and thyrotracheal anastomosis was performed. As positive pressure ventilation of the lungs was required until the anastomosis was fully completed, a 15-mm connector was attached to the extratracheal limb of the T-tube to connect the ventilation circuit. In order to seal off the supraglottic leak through the upper limb of the T-tube, the following novel technique was used to pass a Fogarty catheter into the upper limb of the T-tube: Immediately after incision of the trachea, a suture was attached to the Murphy’s eye of the tracheal tube. The tracheal tube was partially withdrawn during the tracheal resection; then, as the surgeons were ready to insert the T-tube, the tracheal tube was completely withdrawn and the suture to the Murphy’s eye was cut. Next, the proximal end of the suture was tied to the tip of the Fogarty occlusion catheter (Model 62080814F) (Edwards Lifesciences LLC, Irvine, CA, USA) just distal to the balloon. The distal end of the suture was pulled slowly by the surgeon, and the Fogarty catheter was advanced through the mouth and glottis and positioned in the upper limb of the T-tube under direct visual guidance (Figure 1). Then, the balloon of the Fogarty catheter was inflated to provide an occlusive seal. A 15-mm connector was inserted into the extratracheal limb and positive pressure ventilation was commenced. At the end of surgery, inhalational anesthesia was discontinued and muscle relaxation was reversed. The patient awoke and breathed spontaneously. The 15-mm connector was disconnected from the extratracheal limb of the T-tube, and an oxygen mask was placed over both the extratracheal limb of the T-tube and the patient’s face. D. T. Wong, MD (&) Toronto Western Hospital, University of Toronto, Toronto, ON, Canada e-mail: david.wong@uhn.on.ca

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.