Abstract
The interaction between the three-phase voltage source converters (VSCs) and the power grid may cause high-frequency resonant instable problems. Studies have indicated that the non-passivity of VSCs is the main reason that leads to the resonances. The above-mentioned passive means that the equivalent output admittance of the VSC has a positive real part. In this paper, a novel damped Smith predictor is proposed to suppress the resonant instability problem that caused by time delay. The research proved that the proposed Smith predictor can significantly improve the passivity of the VSC by reducing the width of the negative real part at the high-frequencies. Simulation and experimental results demonstrate that the proposed Smith predictor can distinctly improve the robustness of the VSC.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Electrical Engineering & Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.