Abstract

The design of molten salt reactor has high-temperature pipes penetrating the walls of reactor cavity, the working temperature of which is about 530 K higher than the ordinary concrete wall. The insulation of high-temperature pipes is important to prevent local overheating of the walls of molten salt reactor cavity. A heat insulation scheme with multilayer different materials for the high-temperature pipe is analyzed. In order to verify the correctness and rationality of the design, one experimental set-up was built. The maximum relative deviation between the numerical results and experimental ones is 2.74% and the maximum relative uncertainty of the experimental results is 0.62%. The design scheme is used in a molten salt reactor and the maximum temperature of the ordinary concrete wall of the molten salt reactor cavity is 338.58 K, which is within the safety limit value of 343.15 K. The design of heat insulation for high-temperature pipe can also be used in other molten salt reactors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.