Abstract

In this study, an embeddable in-situ corrosion monitoring electrode based on Ce-doped NiFe2O4 was fabricated, and their corrosion performance of the steel rebar was evaluated in the simulated concrete environment under passive and active conditions. The passive and active environment consists of simulated concrete pore solution (SCPS) without and with 3% NaCl. The corrosion performance of embedded steel rebar in concrete was monitored by exposing the concrete specimens under alternate dry and wet condition in 3% NaCl solution. The corrosion behavior of the steel rebar was studied by using open circuit potential, AC-impedance, and potentiodynamic polarization studies. The relative corrosion performance of the embeddable steel rebar was assessed with fabricated corrosion monitoring electrode (FCME) and compared with the surface mounted electrode (SME) by using saturated calomel electrode (SCE). The results revealed that the FCME could use as an in-situ electrode for assessing the corrosion monitoring of the reinforced concrete structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.