Abstract

SummaryTo reduce the impact of the single‐event transient (SET) effect on the high‐precision comparator, based on the common high‐gain pre‐amplification stage structure of the comparator, a new radiation hardened by design (RHBD) method, namely, the sensitive node transient detection feedback latch (SNTDFL) technique, is proposed. The hardening technique avoids comparator erroneous output by detecting the sensitive nodes of the high‐gain pre‐amplification stage. The detection circuit receives the response generated by the high energy particle impacts and feeds the high level back to the sensitive nodes to latch the current comparator state. In this paper, a novel high‐precision SET hardened voltage comparator based on this technique is developed. Through detailed circuit principle and simulation analysis, the functional characteristics and the hardening performance of the high‐precision hardened comparator are verified. Compared with the unhardened and the TMR technique hardened comparator, the SNTDFL technique hardened comparator effectively avoids the erroneous output caused by the SET effect with less overhead and still has excellent functional characteristics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.