Abstract

A novel harmonic elimination PWM (HEPWM) technique for drives and static power converters is presented. The technique can be implemented on-line in real-time using a simple software algorithm, without resorting to any traditional off-line numerical techniques nor extensive lookup tables (LUTs). It is shown that the developed HEPWM technique can be implemented by calculating switching angles using simple algebraic equations and selecting switching states. In comparison with the previous reports which require the calculation of the switching angles in the first sextant, only the switching angles in the first half sextant are required. Simulation and experimental results are presented to confirm and demonstrate the features of the technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.