Abstract

Electrical capacitance tomography (ECT) is one of process tomography technique which is developed rapidly in recent years. ECT is an imaging technique to obtain the internal permittivity distribution of a vessel or pipe by using capacitance electrodes sensor. This method has been integrated with ultrasonic tomography as multimodality system to perform multiphase flow measurement such as crude oil separation and oil process industry. In the present paper, a novel type of ECT sensor was developed using copper FR4 material. The electrode sensors can be flexibly bend or curve to fit the pipe surface for optimum measurement. Thus, every single sensor strip is designed to be functioned independently. Such system has lower sensing capability in the central of the sensing area which often contributes to poor imaging result. This problem can be overcome by combining the ECT with ultrasonic tomography to form a dual modality tomography system. By implementing the new ECT sensor, multiphase flow measurement image results can be achieved. The reconstructed image results are presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.