Abstract

The three-element modified Windkessel model has been widely used to study the characteristics of the systemic arterial system. This model provides most of the features of the systemic input impedance, but does not describe the nonlinear effect of the pressure dependence of arterial compliance. The current investigation examines the hemodynamic consequences of such an inclusion. Simultaneous aortic pressure and flow during control and brief descending aortic occlusion were measured in open chest anesthetized experimental dogs. A numerical procedure was implemented to compute constant compliance linear and nonlinear compliance model-predicted pressure waveforms with flow as the input. Results show that the nonlinear compliance model in general can more accurately predict the measured pressure waveforms during control and during acute pressure loading. The difference between the predicted waveforms is more pronounced when blood pressure is high and when the pulse pressure is large.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.