Abstract

This paper describes the evaluation of a new personal sampler for organic vapors which is totally different from traditional sampling techniques using pumps and adsorption tubes. Sampling of organic vapors is effected by collection on an adsorption substrate contained within a small passive sampler worn by the worker. The collection element is removed from the sampler and subsequently analyzed for organic vapors. The results are equated with the time-weighted-average concentration of contaminants in air. This new sampling device circumvents inherent errors generally associated with sampling pumps and tubes; e.g., changes in pumping rates and variable pressure drops across adsorption tubes. Applications of the sampler were demonstrated on various concentrations of benzene, methyl isobutyl ketone, isooctane, butyl acetate, methyl chloroform, trichloroethylene, butanol and solvent mixtures. Variables studied included the effects of temperature, charcoal lot, and air velocities. In addition, the occurrence of "breakthrough" and effect of time on sample stability were investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.