Abstract

Accurate measurement of solids residence time distribution (RTD) is an important and challenging issue in developing fluidized bed reactors with continuous solids feeding and discharging. In this study, we proposed a new method for measuring solids residence time distribution, where coked bulk material was used for solids tracer and high-precision element analyzers were used to determine solids tracer fraction. A calibration procedure was established to achieve high-accuracy measurement of solids tracer fraction. The following validation tests had successfully proved the pseudo-CSTR solids flow pattern under different operating conditions and the staging effect of an inserted horizontal baffle in a small laboratory-scale fluidized bed cold model, which demonstrate the feasibility and advantages of this new solids RTD measurement method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.