We have developed a method to obtain the ratio error and phase displacement of a single-stage current transformer (CT) by measuring four parameters in a CT equivalent circuit. The method was applied to CTs under test with a primary current in the range 10–20 000 A and a secondary current of 5 A. By determining the errors of the CTs under test using this method, the ratio error and phase displacement of the standard CTs used as a reference in a CT test system could be obtained. This implies the establishment of a traceability chain of a national standard for CTs. The ratio error and phase displacement of the standard CTs obtained in this study are consistent with those measured at the Physikalisch-Technische Bundesanstalt in Germany using the same standard CTs within an expanded uncertainty (k = 2) in the overall primary current range investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.