Abstract

Recent research has shown that electromechanical (E/M) impedance-based techniques are an efficient strategy for damage sensing in the context of structural health monitoring (SHM). The basic principle is to excite the lead zirconate titanate (PZT) sensors attached to the structure and to measure the corresponding electrical impedance. A variation in the electrical impedance indicates a variation in the mechanical impedance and, consequently, structural damage. To measure the electrical impedance, most universities and research centers use expensive, bulky, heavy, and high-powered impedance analyzers, which limit new developments and practical applications. To overcome these issues, this paper presents an efficient and inexpensive methodology for electrical impedance measurement. To verify the efficiency and accuracy of the new methodology, practical tests were carried out, and the results were compared with those obtained using a conventional impedance analyzer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.