Abstract

A new flow passage arrangement is introduced for parallel-plate heat exchanger for cooling channel walls under uniform heat flux. Heat transfer performance of the new double-pass heat exchanger is compared with those of the corresponding single-pass and original double-pass heat exchangers from wall temperature uniformity viewpoint, because total heat transfer is the same for three types of the parallel-plate heat exchangers. Computed results show that wall temperature in the new double-pass heat exchanger has better uniformity compared to the usual one. Despite the advantage of better uniformity in wall temperature, power consumption for handling the specified volumetric flow rate within the new double-pass heat exchanger is greater than those are required within the two others.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.