Abstract
Electrochemical noise (EN) was recorded during the temperature linear scanning period and analyzed using noise thermammetry method. The transition point, separating the Arrhenius plot into two regions, was observed. Below this point, the activation energy of material converse to negative and the corrosion events become spontaneous process. Therefore, this transition point can be as a criterion for the determination of CPT. The effect of inhibitor concentration, surface roughness and ageing time on the CPT were also investigated by means of EN method with comparison of potentiostatic results. These demonstrate the universality and measurement precision of this new criterion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.