This report describes a complication after stent grafting of the aortic arch for residual dissection after ascending aorta and aortic arch replacement for acute type A dissection. One year later, a pseudoaneurysm originating from the proximal suture line and therefore far from the stent graft landing zone developed and fistulized into the pulmonary artery. Possible causes were suture damage during stent deployment and change of system forces after stent placement leading to high tension on the suture line. Emergency surgery was performed. Aortic arch stent grafting is a new and promising technique, but its complications are still not completely known.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.