The Rotational Modulation Collimator (RMC) is a simple and versatile tool for the radiation imaging system with low cost, makes it a reasonable selection for locating and tracking nuclear materials and radiation sources. In this paper, Monte Carlo simulation-based design studies for an alternative RMC which has an extended field-of-view will be presented. Modulation patterns for 5 different hemispherical RMC (H-RMC) designs were simulated for various source locations, and fundamental characteristics of rotational modulation patterns were investigated. Obtained patterns showed variations depending on the source location for most of the H-RMC designs, exhibiting promises for the future development of an omni-directional radiation imager based on a non-position sensitive radiation detector.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.