Abstract

The spectrophotometric determination of gold with 4,4′-bis(dimethylamino)thiobenzophenone has been adapted for routine use in the range 0 to 50 µg of gold.Composite reagent solutions containing 4,4′-bis(dimethylamino)thiobenzo-phenone, acetic acid, sodium acetate and either ethanol or butanol are convenient and stable, if protected from light.The reagents give results with 95 per cent. confidence limits of ±1·2 µg (with the ethanolic reagent) and ±1·5 µg (with the butanolic reagent) of gold for a single determination of the absorbance.Procedures with either reagent are applicable to the determination of up to 50 µg of palladium, silver or mercury.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.