Abstract
The spectrophotometric determination of gold with 4,4′-bis(dimethylamino)thiobenzophenone has been adapted for routine use in the range 0 to 50 µg of gold.Composite reagent solutions containing 4,4′-bis(dimethylamino)thiobenzo-phenone, acetic acid, sodium acetate and either ethanol or butanol are convenient and stable, if protected from light.The reagents give results with 95 per cent. confidence limits of ±1·2 µg (with the ethanolic reagent) and ±1·5 µg (with the butanolic reagent) of gold for a single determination of the absorbance.Procedures with either reagent are applicable to the determination of up to 50 µg of palladium, silver or mercury.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.