Abstract
To increase the fault tolerance for cascaded H-bridge multilevel inverters (CHMIs) based on level-shifted pulse width modulation (LS-PWM), a modified LS-PWM method is proposed for the inverters operating under faulty conditions. To cover both open- and short-device fault cases, two types of switching scheme are included in this PWM method. With this PWM method, the neutral shift can be applied as fault-tolerant control for CHMIs based on LS-PWM. Finally, three-phase-balanced line-to-line voltages and currents with minimum harmonic distortion are produced for the inverter with disabled power cells. In addition, this LS-PWM method has the capability to improve power distribution among the H-bridge power cells under the faulty conditions. Simulation and experimental results show that the proposed PWM method performs satisfactorily to achieve fault tolerance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.