The practical procedures of a recently proposed technique to experimentally determine the I-V characteristics of negative differential conductance (NDC) devices are presented in this paper. The technique employs microwave reflection coefficients together with the measurable portions of the device's I-V characteristics to infer the I-V curve in the negative conductance region where oscillations tend to occur under normal DC bias conditions. The effects of higher harmonics at large signal levels are also taken into account in the calculation. The advantages of the method for high NDC devices have been pointed out in the stability analysis contained in a previously published work. The technique was demonstrated in the case of a low NDC tunnel diode where the agreement between the deduced I-V curve using the described method and the DC measured I-V curve is within 5%. The I-V curve in the negative conductance region for another tunnel diode with much higher negative conductance is also obtained and a self-consistent accuracy of 5% is found. >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.