Abstract
AbstractA method to design the composite insulation structures in pulsed power systems is proposed in this paper. The theoretical bases for this method include the Weibull statistical distribution and the empirical insulation formula. A uniform formula to describe the reliability (R) for different insulation media such as solid, liquid, gas, vacuum, and vacuum surface is derived. The dependence curves of the normalized applied field onRare also obtained. These curves show that the normalized applied field decreases rapidly asRincreases but the declining rates corresponding to different insulation media are different. In addition, ifRis required to be higher than a given level, the normalized applied field should be smaller than a certain value. In practical design, the common range of the applied fields for different insulation media should be chosen to meet a global reliability requirement. In the end, the proposed method is demonstrated with a specific coaxial high-voltage vacuum insulator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.