Abstract

Thermal conductivities of from 2 to 500×10−4 c.g.s. units are measured by comparing the flow of heat through a given sample with that through a standard material. On the basis of repeat runs and checks with literature values, an accuracy of about five percent is estimated for this method. The dimensions of the apparatus limit the face size of both the unknown and standard samples to a maximum of 10 millimeters square; thicknesses of 2 to 10 millimeters are suitable. Values at average temperatures between 30°C and 75°C are reported for nine materials:—sodium chloride, potassium chloride, potassium bromide, calcium fluoride, lithium fluoride (both air-grown and vacuum-grown), silver chloride, thallium bromide-iodide, thallium bromide-chloride, and fused silica.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.