Abstract

A technique is described which allows the study of the concentration of silver-iodide particles produced by a ground generator. It consists of marking these particles with Iodine 131, then filtering the air at the required places with air-borne filters. The iodine is extracted chemically, concentrated in a very small silver iodide disc which is then placed upon a nulcear emulsion. After two weeks the activity is measured by electron track counting. Limitations of the method are given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.