Abstract

Hydraulic performance of clarifiers in water and wastewater treatment plants significantly affects the settling efficiency of suspended particles. Structural and ambient parameters can deteriorate this performance. Through a verified three dimensional numerical study, we evaluated hydraulic performance and settling efficiency in a rectangular clarifier with a nominal hydraulic retention time (HRT) of 1 h and options for structural baffles with angles of 20°, 30°, 45° and 70°. Large eddy simulation and Lagrangian particle tracing were used to trace particles 80 to 850 μm in diameter. A passive scalar tracer study was conducted to reveal discrepancies in nominal and real HRT. By posing a 5 m/s wind, ten different scenarios were simulated. The wind caused 17% and 6% reduction in HRT and settling efficiency, respectively. Baffles improved these indicators with the 45° baffle showing the best performance with an approximate settling efficiency of 93%. The study highlighted the importance of using baffles, in particular for small size particles for which influencing factors such as wind deteriorate their settling efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.