Abstract

We report on a rare case of delayed presentation of ureteric injury with a transobturator mesh kit for anterior vaginal wall prolapse repair along with conventional vaginal pelvic reconstructive surgery: a case of a 56-year-old multiparous, postmenopausal woman with a body mass index of 22.1 kg/m, who had continuous leakage of urine per vagina 28 days after vaginal hysterectomy, mesh-augmented anterior repair with Avaulta Plus Anterior support system kit (CR Bard Inc, Covington, Ga), and sacrospinous ligament fixation for stage IV pelvic organ prolapse. Pelvic computed tomographic scan with contrast revealed an intact bladder, right hydroureteronephrosis, and right ureterovaginal fistula. Immediate laparotomy performed revealed that the right lower mesh arm was entangled with the distal end of the right ureter, 1.5 cm from the ureteric orifice. Category, time, site classification was 4CaT2S5. Right ureteric reimplantation was performed uneventfully. We herein emphasize that the development of a delayed type of ureteric injury is a possible associated complication of transobturator mesh surgery for the prolapse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.