Abstract

First tests of a data acquisition system for linear position-sensitive gas proportional detectors based on an ASIC (application specific integrated circuit) implementing the space–time–space conversion method for parallel readout of delay lines are presented. Using a standard delay line detector a spatial resolution of 0.3mm/channel was achieved corresponding to a time resolution of ≅0.4ns/channel in the ASIC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.