Abstract

A test-retest reproducibility study was performed to define a criterion for stability as opposed to change of motor function of the lower extremity in stroke patients. Forty-nine patients with stroke were examined twice by the same physiotherapist, using the Fugl-Meyer Assessment Scale. The interval between both measurements was three weeks. The mean differences between the first and the second measurement were small, with 0.04 points for the lower extremity scale and 0.92 points for the balance scale, respectively. Intraclass correlation coefficient for the lower extremity scale was 0.86, and 0.34 for the balance scale. The standard error of measurement for each scale was 1.76 and 1.17 points, respectively. The standard error of measurement can be transformed in an 'error threshold', which is a criterion to differentiate real changes from changes due to chance variation or measurement error. As the absence of real change is a parameter for stability, a change of less than 5 points for the lower extremity scale and of less than 4 points for balance confirms stability of motor function.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.