Abstract

This paper describes numerical simulations, using thermal networks, of shield temperatures and radiative and conductive heat losses of a super-insulated cryogenic storage tank operating at 77 K. Interactions between radiation and conductive heat transfer modes in the shields are investigated, by calculation of local shield temperatures. As a new method, fluid networks are introduced for calculation of stationary residual gas pressure distribution in the evacuated multilayer super-insulation. Output from the fluid network is coupled to the iterative thermal network calculations. Parameter tests concern thickness and emissivity of shields, degree of perforation, residual gas sources like desorption from radiation shields, spacers and container walls, and permeation from the inner container to the evacuated insulation space. Variations of either a conductive (thickness of Al-film on Mylar) or a radiative parameter (thermal emissivity) exert crosswise influences on the radiative or conductive heat losses of the tank, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.