Abstract

A comparative analysis of a current source inverter and a voltage source inverter suitable for induction heating and melting applications is presented. Both power supplies considered operate on the principle of load commutation. The comparison is based on criteria such as input power factor, component ratings, maximum and minimum operating frequencies, operation under varying load conditions, inverter starting capability, and system and control simplicity. The voltage source series resonant inverter is found to offer the best overall performance with respect to converter utilization. >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.