Abstract
Objective: To compare the reliability of ligase chain reaction (LCR) to polymerase chain reaction (PCR) in detecting Chlamydia trachomatis endocervical infections.Methods: We conducted a prospective study of 486 patients at risk for chlamydial infection of the endocervix. We obtained two endocervical specimens from each patient and used LCR and PCR to detect C. trachomatis. Discrepant results between the two techniques were resolved by repeat testing and by testing for the major outer membrane protein (MOMP) gene, if necessary. We determined the sensitivity, specificity, positive predictive value, and negative predictive value for each test, using concordant results or MOMP gene results as the “gold standard”.Results: Of the 486 patients, 42 (8.6%) had evidence of C. trachomatis infection after resolution of discrepant results. Of the 42 true positive specimens, 41 were positive by initial LCR and 38 were positive by initial PCR. Of the 444 true negative specimens, none had a positive initial LCR result, while 2 had a positive initial PCR test. Therefore, compared to the gold standard, LCR had a sensitivity of 97.6% and specificity of 100%, while PCR had a sensitivity of 90% and a specificity of 99.5%. The positive and negative predictive values of LCR were 100% and 99.8%, respectively. PCR had a positive predictive value of 95% and a negative predictive value of 99.1%. The difference in sensitivity of LCR versus PCR was not statistically significant (P = .125).Conclusion: LCR and PCR perform equally well in detecting C. trachomatis endocervical infections.
Highlights
Of the 486 patients, 42 (8.6%) had evidence of C. trachomatis infection after resolution of discrepant results
Four patients were positive by ligase chain reaction (LCR) and negative by PCR
Three patients were negative by LCR and positive by PCR
Summary
Of the 486 patients, 42 (8.6%) had evidence of C. trachomatis infection after resolution of discrepant results. Of the 42 true positive specimens, 41 were positive by initial LCR and 38 were positive by initial PCR. Of the 444 true negative specimens, none had a positive initial LCR result, while 2 had a positive initial PCR test. Compared to the gold standard, LCR had a sensitivity of 97.6% and specificity of 100%, while PCR had a sensitivity of 90% and a specificity of 99.5%. The positive and negative predictive values of LCR were 100% and 99.8%, respectively. PCR had a positive predictive value of 95% and a negative predictive value of 99.1%. The difference in sensitivity of LCR versus PCR was not statistically significant (P .125)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.