Abstract

In this study, the effects of rice husk ash (RHA) on various geotechnical properties of cohesive (A- 7-6 group) and cohesionless (A- 1-b group) soils were determined and compared. Atterberg limits, dry density, optimum moisture content, unconfined compressive strength, California bearing ratio, cohesion and angle of internal friction of A- 1-b and A- 7-6 group soils were studied with different percentages of rice husk ash ( 0, 4, 8, 12, 16, 20, and 24). Optimum moisture content, compressive strength, California bearing ratio and cohesion of both soils increased with increase in RHA. Maximum dry density decreased with RHA contents. Angle of internal friction of A- 7-6 soil increased while that of A- 1-b soil decreased with RHA contents. From the point of view of economy and CBR value, A- 1-b soil with 16% RHA is recommended for base materials for field trials in the first instance while A- 7-6 soil with 17% RHA may be recommended only for sub-base materials.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.